home *** CD-ROM | disk | FTP | other *** search
/ NetNews Offline 2 / NetNews Offline Volume 2.iso / news / de / comm / modem / 297 < prev    next >
Internet Message Format  |  1996-08-06  |  3KB

  1. Path: news.rhrz.uni-bonn.de!user
  2. From: uzs706@ibm.rhrz.uni-bonn.de (Dirk von Seggern)
  3. Newsgroups: de.comm.modem
  4. Subject: Re: Leitungsdaempfung in dB ?
  5. Date: Wed, 17 Jan 1996 22:38:21 +0100
  6. Organization: University of Bonn, Germany
  7. Distribution: world
  8. Message-ID: <AD232ADD966811267@rhrz-ts3-p12.rhrz.uni-bonn.de>
  9. References: <4d93lo$bg6@news00.btx.dtag.de>
  10. NNTP-Posting-Host: rhrz-ts3-p12.rhrz.uni-bonn.de
  11.  
  12. In article <4d93lo$bg6@news00.btx.dtag.de>,
  13. jupp.chudzinski@t-online.de (Jupp Chudzinski) wrote:
  14.  
  15. >In message <4cv0p8$m3a@selene.rz.uni-duesseldorf.de> - ruebner@uni-duesseldorf.
  16. >de (Michael Ruebner) writes:
  17. >  :>
  18. >  :>Mein Modem gibt, abhaengig von der Einwahlnummer, Daempfungswerte
  19. >  :>zwischen 10 - 20 dB (was eigentlich: SPL oder A ?) an.
  20. >  :>
  21. >  :>Obwohl ich vermute, dass diese Werte auf eine ziemlich miese
  22. >  :>Leitungs*qualitaet* hinweisen, fehlen mir leider Vergleichswerte...
  23. >  :>
  24. >  :>Wie verlaesslich sind solche Angaben eigentlich und wie werden sie
  25. >  :>ermittelt ?
  26. >
  27. >Was hast Du denn fuer ein tolles Modem, mit dem diese Werte ermittelbar sind?
  28.  
  29. >Auch nach Studium der Doku habe ich keinen Hinweis gefunden. Gibt es dazu einen >Befehl oder muss ein spezielles Register ausgelesen werden?
  30.  
  31. Beim Creatix SG2834 bzw. Skyconnect 28800 V.34 geht das mit AT%L oder bei
  32. bestehendem Connect mit AT%Q:
  33.  
  34. %L      Reports Received Signal Level (at connection to DSP) nnn in -dBm.
  35.          nnn=9 or stronger       reports as 9
  36.          nnn=10 to 45            reports as value directly
  37.          nnn=46 or weaker        reports as 46
  38.  
  39. Returns a value which indicates the received signal level. The value
  40. returned is a direct indication (DAA dependent) of the receive level at the
  41. MDP, not at the telephone line connector.
  42.  
  43. %Q      Report Received signal Quality aka EQM (nnn range 0 to 127)
  44.          nnn=0 to 7 current signal quality excellent (higher rate may be
  45. used)
  46.          nnn=8 to 20 current signal good (best carrier rate for line
  47. condition)
  48.          nnn=21 to 30 current signal poor (lower carrier rate should be
  49. used)
  50.          nnn=31 to 127 signal very bad (or gone), try forcing a lower rate
  51.          NOTE: Modem uses 8 and 20 as rate renegotiation watermarks.
  52.  
  53. Reports the line signal quality (DAA dependent). Returns the higher order
  54. byte of the EQM value. Based on the EQM value, retrain or fallback/fall
  55. forward may be initiated if enabled by %E1 or %E2.
  56.  
  57. Diese Befehle sollten bei jedem Modem mit den Datenpumpen (RC288DPi,
  58. RC288ACL/VFC, RC288ACi/VFC) von Rockwell funktionieren.
  59.  
  60. Dirk
  61.  